Square D HJL36050M72 Motor Circuit Protector, 690 VAC, 50 Amp, 25 kA Interrupt, Three Pole

Square D PowerPacT H Series HJL36050M72 Motor Circuit Protector, 690 VAC, 50 A, 25 kA Interrupt, 3-Pole

Square D PowerPacT H Series HJL36050M72 Motor Circuit Protector, 690 VAC, 50 A, 25 kA Interrupt, 3-Pole HJL36050M72

PowerPact H-frame motor circuit protectors (MCP) are instantaneous trip circuit breakers designed to offer short circuit protection for motors. The unique design of the PowerPact MCPs accommodates transient motor inrush current without nuisance tripping. These motor protectors accept the same accessories and terminals as equivalent PowerPact circuit breakers. This unit has lugs on both the line and load side. This PowerPact H, 50 A, 3-pole, motor protector has a breaking capacity of 25 kA at 600 VAC. PowerPact electronic motor circuit protectors accept the same accessories and terminals as equivalent PowerPact circuit breakers. This breaker has lugs on both the line and load sides. This breaker has a continuous current rating of 80%. PowerPact H motor circuit protectors comply to UL, CSA and IEC standards and are CE marked.
Square D Motor Circuit Protector, Series: PowerPacT H Series, 50 A, 690 VAC, 50/60 Hz, 25 kA Interrupt Rating, 3 Poles, H Frame, Thermal Magnetic Trip, 84 to 546 A Trip Range, Lug Terminal, NEMA Enclosure, 14 to 3/0 AWG Wire, Lug Mounting, 28 to 158 deg F, 4.09 in Width, 3.39 in Length, 6.42 in Height, Black

Amperage Rating      :      50 A
Color      :      Black
Enclosure Type      :      NEMA
Frame Type      :      H
Frequency Rating      :      50/60 Hz
Height      :      6.42 in
Interrupt Rating      :      25 kA
Length      :      3.39 in
Mounting Type      :      Lug
Number of Poles      :      3
Series      :      PowerPacT H Series
Temperature Rating      :      28 to 158 deg F
Terminal Type      :      Lug
Trip Range      :      84 to 546 A
Trip Type      :      Thermal Magnetic
Voltage Rating      :      690 VAC
Width      :      4.09 in
Wire Size      :      14 to 3/0 AWG
  • Molded case circuit breaker rated at 50 A
  • Utilizes two methods to detect electrical faults - electromagnet's and bimetal switch
  • The current capacity that this circuit breaker is able to interrupt before breaking is 25 kA
  • Utilizes 4-1/2 in of the I-Line mounting space
  • pdfCatalog https://assets.unilogcorp.com/267/ITEM/DOC/Square_D_HJL36030M71_Catalog.pdf
  • pdfInstruction/Installation Manual https://assets.unilogcorp.com/267/ITEM/DOC/Square_D_HJL36030M71_Instruction_Installation_Manual.pdf
  • pdfLine Drawing https://assets.unilogcorp.com/267/ITEM/DOC/Square_D_HJL36030M71_Line_Drawing.pdf
  • pdfOwners/User Manual https://assets.unilogcorp.com/267/ITEM/DOC/Square_D_HJL36030M71_Owners_User_Manual.pdf
  • pdfSpecification Sheet https://assets.unilogcorp.com/267/ITEM/DOC/Square_D_HJL36050M72_Specification_Sheet.pdf